WS6 1.3 2x6 Wood Stud Wall - Gypsum, Fiberboard Sheathing, Mineral Wool Insulation

One-Hour Fire-Rated Loadbearing Wood-Frame Wall Assemblies

Two-Hour Fire-Rated Loadbearing Wood-Frame Wall Assemblies


One-Hour Fire-Rated Wood Floor/Ceiling Assemblies

Two-Hour Fire-Rated Wood Floor/Ceiling Assemblies




Please select a file:  right click and save target as .dxf

right click and save target as .dwg

right click and save target as .dwf

right click and save target as .dxf

right click and save target as .dxf


Download Instructions:

1) IMPORTANT:
Before downloading DWF files, please make sure you have Autodesk® DWF Viewer installed on your computer. You can download this program at this link: Autodesk® DWF Viewer.
This program is used to help users view and print Cad details without installing Autocad. It is free, easy to use, and should only take a few minutes to download and install.

2) If a dialogue box does not prompt you to open or save the file when a button is clicked, please right click the button and go to "save target as" or "save link as". Then save the file with the appropriate extension corresponding to the file you are downloading. (i.e.: WFCM Fig 1.1.dwg)

1. Framing: Nominal 2x6 wood studs, spaced 16 in. o.c., double top plates, single bottom plate

2. Interior Sheathing: 5/8 in. Type X gypsum wallboard, 4 ft. wide, applied horizontally, unblocked. Horizontal application of wallboard represents the direction of least fire resistance as opposed to vertical application.

3. Exterior Sheathing: 7/16 in. wood structural panels (oriented strand board), applied vertically, horizontal joints blocked

4. Gypsum Fasteners: 2-1/4 in. Type S drywall screws, spaced 12 in. o.c.

5. Panel Fasteners: 6d common nails (bright) - 12 in. o.c. in the field, 6 in. o.c. panel edges

6. Insulation: 5-1/2 in. thick mineral wool insulation (2.5 pcf, nominal)

7. Joints and Fastener Heads: Wallboard joints covered with paper tape and joint compound, fastener heads covered with joint compound

Test -  Tests conducted at the Fire Test Laboratory of National Gypsum Research Center, Test No: WP-1244 (Fire Endurance & Hose Stream) on February 25, 2000

Third Party Witness -  Intertek Testing Services, Report J99-27259.2