WS4 1.3 2x4 Wood Stud Wall - Gypsum, Fiberboard Sheathing, Mineral Wool Insulation

One-Hour Fire-Rated Loadbearing Wood-Frame Wall Assemblies

Two-Hour Fire-Rated Loadbearing Wood-Frame Wall Assemblies


One-Hour Fire-Rated Wood Floor/Ceiling Assemblies

Two-Hour Fire-Rated Wood Floor/Ceiling Assemblies




Please select a file:  right click and save target as .dxf

right click and save target as .dwg

right click and save target as .dwf

right click and save target as .dxf

right click and save target as .dxf


Download Instructions:

1) IMPORTANT:
Before downloading DWF files, please make sure you have Autodesk® DWF Viewer installed on your computer. You can download this program at this link: Autodesk® DWF Viewer.
This program is used to help users view and print Cad details without installing Autocad. It is free, easy to use, and should only take a few minutes to download and install.

2) If a dialogue box does not prompt you to open or save the file when a button is clicked, please right click the button and go to "save target as" or "save link as". Then save the file with the appropriate extension corresponding to the file you are downloading. (i.e.: WFCM Fig 1.1.dwg)

1. Framing: Nominal 2x4 wood studs, spaced 16 in. o.c., double top plates, single bottom plate

2. Interior Sheathing: 5/8 in. Type X gypsum wallboard, 4 ft. wide, applied vertically, unblocked

3. Exterior Sheathing: 1/2 in. fiberboard sheathing. Alternate construction - minimum 1/2 in. lumber siding or 1/2 in. wood based sheathing.

4. Exterior Siding: 3/8 in. hardboard shiplap edge panel siding. Alternate construction - lumber, wood based, vinyl, or aluminum siding.

5. Vapor Barrier: 4-mil polyethylene sheeting

6. Insulation: 3-1/2 in. thick mineral wool insulation (2.5 pcf, nominal)

7. Gypsum Fasteners 6d cement coated box nails spaced 7 in. o.c.

8. Fiberboard Fasteners 1-1/2 in. galvanized roofing nails - 6 in. o.c. in the field, 3 in. o.c. panel edges

9. Hardboard Fasteners: 8d galvanized nails - 8 in. o.c. in the field, 4 in. o.c. panel edges

10. Joints and Fastener Heads: Wallboard joints covered with paper tape and joint compound, fastener heads covered with joint compound

Test -  Tests conducted at the Gold Bond Building Products Fire Testing Laboratory, Test No:WP-584 (Fire Endurance & Hose Stream) on March 19, 1981

Third Party Witness -  Warnock Hersey International, Inc., Report WHI-690-003